Return to site

Landis Gyr Rxs4e Manual

broken image


The next generation of commercial metering begins with the E650 S4x. The S4x sets a new standard for versatility right out of the box, with four quadrant measurements of active and reactive energy, load profile and TOU without a battery… Read more Teairra mari no daddy.

Description:

A Landis+Gyr specialist is assigned and provides additional, escalated procedures as determined necessary by Landis+Gyr support services staff. Landis+Gyr exercises commercially reasonable efforts to provide a workaround or include a fix for the issue in the next maintenance release. Landis+Gyr E450 Landis+Gyr - View and Download Landis+Gyr E650 Series 4 user manual online. Electricity Meters IEC/MID Industrial and Commercial. E650 Series 4 Measuring Instruments pdf manual download. Also for: Zmd400at, Zmd400ct, Zfd400ct, Zfd400at.

Kyocera taskalfa 180 gx driver for mac pro. The S4x also provides the metrics utilities need at a higher resolution than most competitive meters to take full advantage of advanced grid management technologies. It comes with significantly more RAM, ROM and non-volatile memory for load profile, self-reads and event logs. The meter is available with multiple hardware options that further expands its capabilities.

Landis Gyr Rxr S4e Manual

Raising the bar on security and tamper detection, the meter provides both tilt and vibration sensing, and a dedicated Hall Effect sensor can detect strong magnetic field presence. The S4x brings value and features together to provide industry-leading capabilities for metering critical accounts.

Features

LOAD PROFILE:

  • 16 CH 256K standard, 1MB option
  • 2nd recorder option
  • 32 bit data storage

SUPERIOR METRICS:

Landis Gyr Rxs4e Manual Transmission

  • Four-quadrant measurement
  • Delivered and received kW, kVA and kVAR demands
  • Two alternate methods of VAR and VA calculation
  • Milli-unit energy and demand resolution
  • Micro-unit instrumentation resolution

UNIQUE SECURITY:

  • Magnetic tamper detection
  • Cover removal switch
  • Tilt and vibration sensor

HARDWARE OPTIONS:

Manual

Landis Gyr Rxs4e Manual Transmission

  • Four-quadrant measurement
  • Delivered and received kW, kVA and kVAR demands
  • Two alternate methods of VAR and VA calculation
  • Milli-unit energy and demand resolution
  • Micro-unit instrumentation resolution

UNIQUE SECURITY:

  • Magnetic tamper detection
  • Cover removal switch
  • Tilt and vibration sensor

HARDWARE OPTIONS:

  • Enhanced Gridstream RF module
  • I/O board
  • Three-phase power supply




broken image